Not connected. Needs Chrome, Edge or another Chromium browser.
0ADC 0005).echo 'SUBSYSTEM=="usb", ATTR{idVendor}=="0adc", ATTR{idProduct}=="0005", MODE="0660", TAG+="uaccess"' | sudo tee /etc/udev/rules.d/70-sam-funktrainer.rulessudo snap connect chromium:raw-usb.Shots are saved automatically in this browser only. Use JSON under Saved sessions to keep a copy or move it to another computer.
0.0 rings, 0 shots
Prints the selected target or the calibration sheet at the size that matches your real distance to the target. Print at 100 % ("actual size", not "fit to page"); the ruler on the sheet must measure exactly 100 mm.
Warning: these functions change settings stored inside the receiver and the gun sensor. They follow what the original software does, but this project has not tested them on real hardware. A wrong value can leave the sensor unreachable (radio channel) or the system unusable until the old values are written back, and no factory reset is known. The settings are backed up in this browser automatically when they are read and again right before every write. Export a backup to a file before you start.
How weak a trigger click may be and still count as a shot. Lower it if loading the gun triggers shots. The original software offers 0–100 %, default 85.
In use: –, power-on default: –
Receiver and sensor must use the same channel. Change it only to avoid interference from another trainer nearby.
Receiver: –, sensor: –
Tries channels 1–4 on the receiver until the sensor answers. Changes only the receiver's current channel,
not its stored setting. Use it when the sensor is not reachable.
Print the calibration sheet ("Targets and printing") and fix it on the target unit. Aim at each mark in turn, hold still, and press Capture or fire a shot. Keep "New formula" and "Mount angle" unchanged afterwards.
Not running.
Taken when the settings are read and differ from the last backup, and right before every write. Kept in this browser; the first backup of each device is never removed automatically.
Every setting stored in the receiver and the sensor. Changed fields are outlined; nothing is written before you confirm.